631-256-5903
info@enerac.com

Supported Products

1) Enerac 942xp

Combustion Efficiency Testing- 942xp

2) Enerac 942

Combustion Efficiency Computer- 942

3) Enerac 842

Combustion Efficiency Analyzer-842

4) 200EX

Low-Cost Combustion Analyzer-200ex

The ENERAC Model 200EX Emissions Analyzer is hand held state of the art analyzers designed for the following tasks:

  • To measure the emissions of carbon monoxide, oxides of nitrogen, sulfur dioxide and oxygen from stationary and mobile combustion sources.
  • To assist the operator of a combustion source with the task of optimizing its performance and saving fuel.
  • To be used as a management tool to assist the plant manager with keeping records and controlling costs.

The ENERAC Model 200EX is easy to carry and utilize the latest technology; reliable flue type electrochemical sensors manufactured by the largest sensor manufacturer to measure emissions.

The ENERACs use sophisticated electronics and programming design for increased accuracy and flexibility. They measure 2 temperatures and 5 different stack gases. They compute efficiency of combustion as well as excess air and carbon dioxide. They communicate with a variety of other computers via its RS-232 port. They have a library of 6 fuels and over 30 diagnostic and help messages and can operate either on its rechargeable batteries, AC power, or from a set of four AA alkaline cells.

5) 400

Download Manual 400x Download Manual 400ems

Micro Emissions Analyzer-400x
The ENERAC model,400X-EMS is designed as
modular system, permitting the installation in the field of most of the various
available options. This manual describes the complete instruments equipped with
all the options. The available options on the 400X-EMS are
as follows:

1) 2″ ENERAC Printer.
2) Nitric oxide (NO) measurement capability.
3) Nitrogen dioxide measurement capability.
4) Sulfur dioxide (SO2) measurement capability.
5) Emissions units option (lbs/MBTU & Grams/Bhp-hour).
6) CD-ROM with custom program (ENERCOM TM for WINDOWS TM) for MS-DOS personal computer.
7) 36″ or 48″ inconel probe option.
8) Custom fuel option. (Either at the factory, or programmable using the ENERCOMTM for WINDOWSTM
option.

Any combination, or all of these options are available to meet the customer’s
requirements.
Various cables and attachments are available for special connections to the Micro
Emissions Analyzer.
In addition, high resolution 0-200 PPM and extended range 0-4000 PPM versions
are available on request. (0-10,000 PPM and 0-20,000 PPM available on carbon
monoxide only).

6) 3000

3000-EPA Reference Method

NEW GENERATION COMPLIANCE LEVEL ANALYSER
Advanced EPA reference method emissions analyzer using SEM electrochemical sensor technology to measure CO, NO, NO2, & SO2. Also measures Oxygen, Combustibles, Stack Temperature and Stack Draft. Emssions system includes unique permeation-drier sample conditioning.Enerac 3000 Product Image
Advanced SEM Sensors
QA/PCM – Quality Assured Precision Control Modules
QA/PCM – Quality Assured Interference Protection
QA/CCP – Quality Assured Calibration Certification Protocol
Only refurbished units available

The Enerac 3000 SEM provides facility operators a low cost, easy-to-implement capability to develop timely and representative data for CAAA requirements:
NOx RACT
Operating Permits
CEMS Back-up
Enhanced Monitoring
Audits
Emission Rates

UNIQUE FEATURES

Enhanced Integrated Sample Conditioning System
This is a unique battery operated permeation dryer conditioning system. It has been shown to remove excess water vapor without any loss to the nitrogen dioxide and sulfur dioxide components of the stack gases.

Electrochemical SEM(tm) Sensors
These are the most advanced electrochemical sensors specifically designed for emisisons measurements. SEM sensors are available for the measuremenst of nitric oxide, nitrogen dioxide, carbon monoxide and sulfur dioxide components of the stack gases.

7) 3000E

Electrochemical Emissions Analyzers-3000E

The ENERAC Model 3000E is the most advanced and accurate electrochemical emissions analyzer ever produced. With its range of automatic QA/QC capabilities, the Enerac 3000E provides accurate, documented, defensible data for compliance monitoring purposes, e.g. NSR, Title V Periodic Monitoring, CAM Plan Development, Emission Trading, PAL, Audits, etc.

Unique features include Stack Velocity / Flow Rate measurements and stack emission calculations according to EPA reference methods. Uses the latest SEMelectrochemical sensor technology to measure CO, NO, NO2, SO2. Also measuresOxygen, Combustibles, Stack Temperature and Stack Draft. Emssions system includes unique permeation-drier sample conditioning.
NDIR (Non-dispersive Infrared) Model Enerac 3000E-3IR measures hydrocarbons, CO, and CO2.

The Enerac 3000E series:

  • Meets All the Performance Specifications of EPA’s Test Method for the Determination of Nitric Oxide, Nitrogen Dioxide, and NOx Emissions from Stationary Combustion Sources by Electrochemical Analyzer,CTM-022. (Performance Specifications are Equivalent to Method 7E)
  • Meets All the Performance Specifications of EPA’s Method 2, Determination of Stack Gas Velocity and Volumetric Flow Rate (Type S Pitot Tube), 40 CFR 60 Appendix A.
  • Important QA/QC Capabilities Are Always Available to Insure Accurate, Documented, Defensible Data. They Include:
    • Automatic Calibration Certification Protocol Tests and Documents Proper Sensor and Interference Rejection Filter Performance before each test
    • Replaceable Interference Rejection Filters to Insure Specificity
    • Dual Range Sensors to Adjust a Sensor’s Sensitivity Range to Accommodate Different Measurement Ranges (NO: 5 – 5000 PPM)
    • Auto Temperature Control System for the NO Sensor
  • Integrated Capabilities Provide Mass Emissions Data
  • Advanced Communications and Data Management:
    • Two Way Communications Bring Factory Assistance to Your Site
    • Automatically Calculates lb/mmbtu, gr/Bk-hp-hr; O2 reference adjustment, lbs/hr., tons/year for (CO2)
    • Enercom for Windows Software Captures, Stores and Graphs Data in a Variety of Common Formats for Direct Use by Major PC Programs
  • Enerac’s Comprehensive Field and Factory Training

Enhanced Integrated Sample Conditioning System
This is a unique battery operated permeation dryer conditioning system. It has been shown to remove excess water vapor without any loss to the nitrogen dioxide and sulfur dioxide components of the stack gases.

Electrochemical SEMTM Sensors
These are the most advanced electrochemical sensors specifically designed for emisisons measurements. SEM sensors are available for the measuremenst of nitricoxide, nitrogen dioxide, carbon monoxide and sulfur dioxide components of the stack gases.

8) 2000

Combustion Management System-2000

The ENERAC Model 2000 is designed as a rugged and reliable and portable
service tool for use as follows:

• To assist the boiler operator in getting maximum performance out of his
boiler or furnace.
• To be used as a management tool to assist the plant manager with keeping
records and controlling costs.
• To monitor compliance with environmental regulations.

The ENERAC model 2000 has been designed as a modular system, permitting the

installation in the field of all the various available options. This manual describes

the complete instrument equipped with all the options.

The available options on the model 2000 are as follows:

1. 4″ SEIKO Printer
2. Plotter Printer capability (Requires Printer)
3. Oxides of nitrogen (NOX) measurement capability
4. Sulfur dioxide (SO2) measurement capability
5. Internal 99 test storage option
6. Internal modem for telephone communication
7. Emissions option. (Performs calculations in mg/m3 or lbs./MMBTU corrected ko any oxygen reference)
8. CD-ROM or 3.5″ diskette with custom program (ENERCOM for Windows)for MS-DOS personal computer
9. 24″, 36″ or 48″ inconel probe option
10. Custom fuel option. (Either at the factory, or remotely programmable, if the

ENERAC is equipped with a modem or as a menu selection on SHARP
computer).

9) 2000E

Emissions Monitoring System-2000E

The ENERAC model 2000 has been designed as a modular system, permitting the
installation in the field of all the various available options.
The ENERAC model 2000E is supplied with either one of two probes:
A. Model 2000E- Standard probe & water trap
B. Model 2000EP- Emissions probe for accurate measurement of NO2 & SO2.
Additional available options on the model 2000 are as follows:
1. 4″ SEIKO Printer
2. Plotter Printer capability (Requires Printer)
3. NOX measurement using NO and NO2 sensors. (For NO2 sensor,emissions probe is required!)
4. Sulfur dioxide (SO2) measurement capability. (For SO2 sensor,emissions probe is required!)
5. Internal 70 test storage option
6. Internal modem for telephone communication
7. Emissions option. (Performs calculations in mg/m3 or lbs./MMBTU , orgrams/BHP-HR corrected to any oxygen reference)
8. CD-ROM or 3.5″ diskette with custom program (ENERCOM for Windows)
9. 24″, 36″ or 48″ inconel probe option